Enabling Or Disabling Privacy Zones (Pz); Deleting Privacy Zones One At A Time; Setting The Privacy Zone Security Level - Honeywell ACUIX Installation And Configuration Manual

Ptz high speed analog dome camera
Hide thumbs Also See for ACUIX:
Table of Contents

Advertisement

Configuration
Task/Action (with Default)

Enabling or Disabling Privacy Zones (PZ)

1.
Select 6 Function Programming
2 Enable/Disable PZ
2.
Navigate to the Enabled column and select Y (yes) for enable
(default) or N (no) for disable.
When a privacy zone is enabled, it is assigned the highest
unused priority available.
If a privacy zone is disabled, the programming is saved, but
the video is not masked when the dome moves into the
programmed privacy zone area.
ENABLE/DISABLE PZONE MENU
ZONE
ID
-
1
2
3

Deleting Privacy Zones One at a Time

1.
Select 6 Function Programming
4 Delete Privacy Zones.
2.
Locate and select the applicable privacy zone to delete.
The message Delete Success displays or, if the selected
privacy zone number is not programmed, Does Not Exist
displays.

Setting the Privacy Zone Security Level

1.
Press 75
Preset.
The Administrator Login Screen opens.
2.
Enter the 4-digit PIN. The default is 1000.
The Password Settings window opens.
3.
Select 4 PrivZone Security Level.
4.
Set the privacy zone security level to High (default) or Low.
If the security level is set to High, you cannot program the
privacy zone at a zoom level of more than 10X and the
mask size is increased after a zone is programmed. Also,
while zooming in/out, the patch size increases to prevent
objects from being uncovered.
If the security level is set to Low, you can program the
privacy zones at any zoom level and the mask size is not
increased after a zone is programmed. This means that
when you zoom in or out quickly, the privacy zone may
uncover the object.
104
Table 5-6
Privacy Zone Functions
3 Privacy Zone Options
ZONE
NAME
ENABLED
-
PRIVACY 1
Y
PRIVACY 2
Y
PRIVACY 3
Y
3 Privacy Zone Options
Notes
This menu is available only when
using MAXPRO-mode, VCL, UTP and
Pelco P or D protocols.
To move between the rows on the
same page, move the joystick up or
down (MAXPRO-mode, VCL,
VCL-UTC, Pelco P or D).
To move between pages (if there are
more than six privacy zones) move
the joystick left or right
(MAXPRO-mode, VCL, VCL-UTC,
Pelco P or D).
Existing programming does not have to
be deleted to be reprogrammed. You can
edit the coordinates for an existing mimic
tour, privacy zone, preset, or Sector by
following the applicable programming
procedures
This menu is only available with
MAXPRO-mode, VCL, UTP and Pelco P or
D protocols.
This menu is available with all protocols.