Troubleshooting

Checking the DVR Protocol Matches the Dome Protocol

130
1.
Ensure DIP switches SW5 and SW6 are set for the correct protocol, baud rate, and
parity. The dome must be set the same as the control equipment.
2.
Ensure the controller is matched to the correct dome address. Each dome has a
unique address used for controlling it. Check the rotary switches on the scan
assembly board.
3.
Power down all system components for 15 seconds and then re-apply power to
reset the dome. Manually control the dome and verify that the dome finds home.
4.
For the wiring, make sure that:
the data wiring is connected at the terminal strip in the housing.
any bare wires are not touching each other.
the wire insulation is stripped back far enough for a good connection.
5.
If there are multiple domes in the system, exchange the scan assembly in question
with one from another housing. Set the address of the exchanged scan assembly to
the existing unit. Call up the dome at the controller and if control returns, the
problem is isolated to that scan assembly.
Honeywell DVRs must be configured to use the protocols in the following table to ensure
the dome functions correctly. Use the following table and figures to troubleshoot these
types of installations.
Table B-1
DVR Protocol Settings
DVR
DVR Protocol
HRXD
Diamond, VCL protocol
Fusion
HD6 protocol
Rapid Eye™
KD6 protocol
Scan Assembly
Protocol
Diamond/VCL protocol
MAXPRO-mode
MAXPRO-mode
Controller
HJZTP