Installation

Step 1: Set the Switches on the Housing Interface Board

Pendant Housing
U3
SW2
UTP/coaxial selection
SW2 shown ON (with
UTP enabled)
BNC connector
If using contact inputs,
also removable
terminal blocks on J4
RS485 termination switch
SW1 shown in ON
position (terminated)
36
Figure 3-1
Pendant, In-ceiling, and Rugged Housing Interface Boards
In-ceiling Housing
Interface board
Field wiring access holes
Figure 3-2
Housing Interface Board Layout
J4
SW1
Rugged Housing
J3
J7
Wiring access hole
J1
Fan
Removable
terminal blocks on
J1 and J6
J6