I/O Signal When Cc-Link Ver.1 One Station Is Occupied (Pr.544 = 1) - Mitsubishi Electric FR-A8NC Instruction Manual

Plug-in option cc-link communication function
Hide thumbs Also See for FR-A8NC:
Table of Contents

Advertisement

6.2.2

I/O signal when CC-Link Ver.1 one station is occupied (Pr.544 = 1)

 Remote I/O (32 points)
Same as when Pr.544 = 0 (Refer to
 Remote register
Address

Upper 8 bits
RWwn
Monitor code 2
Set frequency (0.01 Hz increments) /
RWwn+1
torque command
Link parameter
RWwn+2
extended setting
RWwn+3
Write data

Setting "3" or "5" in Pr.804 during torque control under Real sensorless vector control or vector control sets torque command in RWwn + 1.

"n" indicates a value determined according to the station number setting.
48
I/O SIGNAL LIST
page
45)
Description
Lower 8 bits
Monitor code 1
59
59

Instruction code
59
59
Refer
to
Address

Upper 8 bits
page
RWrn
First monitor value
RWrn+1
Second monitor value
RWrn+2
Reply code 2
RWrn+3
Read data
Description
Lower 8 bits
Reply code 1
Refer
to
page
62
62
62
62