3. Cut the aluminum tape and braid.
NOTE
• Where possible, round the cable tip that is cut off with a tool such as nippers. If the cable is not rounded, it may get
caught in the middle of a plug, without fully entering into the plug.
• If required, apply an insulation treatment to the shielding wire area where it is not covered by the one-touch
communication connector plug.
(2) Plug cover check
Check that a plug cover is snapped into a plug
NOTE
• Do not push the plug cover onto the plug before inserting a cable. Once crimped, the plug cover cannot be reused.
4. Straighten the drain wire and twist it from the root.
(Twist seven times or more per 3 cm.)
DA (Blue)
DB (White)
DG (Yellow)
Drain wire
Plug
DA (Blue)
DB (White)
DG (Yellow)
Drain wire (AWG20)
3 cm
Plug cover