8.2

Program example for setting the operation mode

The following explains a program to write various data to the inverter.
The following explains a program to change the operation mode of station 1 inverter to network operation.
• Operation mode write code: HFB (hexadecimal)
• Network operation set data: H0000 (hexadecimal) (Refer to
• The reply code at the time of instruction code execution is set to D2. (Refer to
X0
X0F
X1
0
M0
X20
7
M300
11
M301
X100F
13
M302
X100F
22
28
78
PROGRAMMING EXAMPLES
SW80.0
page
66)
page
M0
Check the data link status of the station 1
PLS M300
SET M301
MOV H0FB W102
Write operation mode write code (HFB)
to RWw2 and set data (H0000) to RWw3.
MOV H0
W103
SET Y100F
Turn on the instruction code execution
request (RY0F)
RST M301
SET M302
Read reply code (RWr2) to D2 when the instruction
MOV W2
D2
code execution completion (RX0F) turns on.
Turn off the instruction code execution
RST Y100F
request (RY0F)
RST M302
END