The following explains a program to read monitor functions of the inverter.
The following program reads the output frequency of station 1 inverter to D1.
Output frequency read code: H0001 (hexadecimal)
Refer to
page 70
for the monitor codes.
(Example) The output frequency of 60Hz is indicated as H1770 (6000).
X0
X0F
X1
0
M0
X20
7
15
80
PROGRAMMING EXAMPLES
SW80.0
X100C
M0
Check the data link status of the station 1
Set monitor code (H01) of output frequency
MOV H1
W100
to RWw0.
Turn on the monitor command (RY0C)
Y100C
Read output frequency (RWr0) to D1
MOV W0
D1
when the monitoring (RX0C) turns on.
END