3.2

System configuration example

(1) Programmable controller side
Load the "QJ61BT11N", "L26CPU-BT", "L26CPU-PBT", "LJ61BT11", "A1SJ61QBT11" or "A1SJ61BT11" "CC-Link system master/
local module" on the main or extension base unit having the programmable controller CPU used as the master station.
(2) Inverter side
Mount the plug-in option (FR-A8NC) on the inverter.
(3) Connect the master station of the CC-Link programmable controller unit to the CC-Link communication connector of FR-
A8NC with the CC-Link dedicated cable.
Manual of the CC-Link master station
QJ61BT11N type
CC-Link System Master/Local Module
User's Manual ...SH-080394E
L26CPU-BT type/L26CPU-PBT type/LJ61BT11 type
CC-Link System Master/Local Module
User's Manual ...SH-080895E
A1SJ61QBT11 type
CC-Link System Master/Local Module
User's Manual ...IB-66722
A1SJ61BT11 type
CC-Link System Master/Local Module
User's Manual ...IB-66721
NOTE
• When the CPU has automatic refresh function (example: QnA series CPU)
When the END instruction is executed by the programmable controller CPU, the buffer memory is automatically
refreshed to enable communication with a remote device.
• When the CPU does not have automatic refresh function (example: AnA series CPU)
Sequence ladder logic is configured to perform direct communication with the buffer memory of the master station and
to enable communication with a remote device
22
WIRING
Master
station
QJ61BT11N,
etc.
Terminating
resistor
Power
supply
CC-Link dedicated cable
Inverter
Inverter
Up to 42
units can be
connected
when only
inverters are
connected
Power
Motor
supply
Remote device station
Terminating
resistor
Motor