Refi t and Check Window
1. Place the window centrally against the engine unit and
resting on the support at bottom front of the engine.
2. Pull the clamping bars forward and rotate inwards to
secure the top of the window.
3. Fit the two spring loaded bolts through the bottom of
the window and tighten to secure the bottom of the
window.
4. Pull the top of the window forward and release to
ensure the springs return it in position.
5. Similarly check the bottom of the window by pulling
it forward and releasing.
IMPORTANT: To ensure a safe operation, ensure that
the spring-loaded mechanism functions properly.
6. Apply light hand pressure against the window frame
sides to bed in the window seal.
7. If the Hot Glass Warning plate has been removed
from the front lower corner of the window,
reinstall it by sliding it between the glass and
the frame as indicated.

Set-up Remote Control

The receiver and the handset of the remote control sys-
tem must be initially synchronized before the fi rst use.
1. Insert alkaline batteries in the remote control
receiver and handset. The receiver is located left
of the control valve under the burner module.
2. With a sharp object, press and hold the receiver's
reset button until you hear one short and one long
beeps. Release the reset button after the second
beep.
3. Within the subsequent 20 seconds, press the small
fl ame button (
) on the remote handset until you
hear two short beeps confi rming the synchronization
is set.
This is a one time setting only and is not required when
changing the batteries in the remote receiver. The
remote control system is now ready to use.