Prepare Vent Outlet - Valor Portrait 530ILN/ILP Installation & Owner's Manual

Dv gas fireplace heater
Hide thumbs Also See for Portrait 530ILN/ILP:
Table of Contents

Advertisement

QUALIFIED
INSTALLER

Prepare Vent Outlet

Co-axial Installations
1. Fit the adapter 817VAK over
the appliance vent collars
pushing on fi rmly. Align the
adapter so that the seam
on horizontal pipes is not
at the bottom—check by
temporarily fi tting a pipe.
2. Drill through the adapter
outer tube and appliance
outer collar for #6 screws.
Make sure that the drill
does not penetrate the inner
tubes.
3. Secure the adapter to the outer collar with
two #6 thread cutting screws supplied.
Co-linear Installations using Listed Generic
Adapter Box
1. Fit the adapter 817VAK over the appliance vent
collars pushing on fi rmly.
2. Fit and fully twist-lock the co-axial-to-co-linear
adapter to the 817VAK adapter.
3. Keeping the connector and adapter fully twist-
locked, rotate them so that the air inlet collar
on the connector is at the bottom.
4. Drill through the adapter outer tube and appliance
outer collar for no. 6 screws. Make sure the drill
does not penetrate the inner tubes.
5. Secure the adapter to the outer collar with two
no. 6 thread cutting screws supplied.
3" Exhaust
3" Inlet
30
Installation
817VAK
Co-linear Installations using Valor 556CLA
Co-linear Adapter
(Note: Instructions may vary as 556CLA may be in-
stalled on Top or Back of Heater.)
1. Remove the blank plate and gasket to gain access
to the exhaust spigot. Retain the plate and gasket
for re-use later.
2. Remove the existing outer intake plate. Retain the
gasket only for re-use.
3. Remove the existing
exhaust spigot—the
gasket below
should
remain on
the heater.
Re-use gaskets
if in good
condition.
If not, clean
and use
supplied gaskets.
Remove existing outlet
4. Install the new co-linear exhaust spigot re-using
existing screws. Ensure all screws are reinstalled
tightly.
5. Install the new co-linear outer plate (note: up/down
front/back orientation on drawing) re-using existing
gasket and screws. Use 6 additional screws
supplied to seal outer plate to gasketed fl ange of
exhaust spigot. Connect the 3-inch diameter fl ex
liners directly to outer plate collars using sheet
metal screws.
Note: "exhaust" & "intake" must correspond
with roof or wall termination.
Gaskets
This is the bottom edge when installing as rear outlet
This is the front edge when installing as top outlet
Replace existing outlet
with 556CLA kit
Exhaust
collar

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents