7. With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached to
the rear of the burner. If needed, keep
pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, refer to
Troubleshooting, pages 27 though 29.
Also contact a qualified service technician
or gas supplier for repairs. Until repairs
are made, light pilot with match. To light
pilot with match, see Manual Lighting
Procedure.
8. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
Note: If pilot goes out, repeat steps 5
through 8. This heater has a safety inter-
lock system. Wait one (1) minute before
lighting pilot again.
9. Turn control knob counterclockwise
to the desired heating level. The main
burner should light. Set control knob
between High (5) and Low (1).
The thermostat sensing bulb measures the
temperature (depending on housing con-
struction). The thermostatic control used on
this model differs from standard thermostats.
Standard thermostats simply turn the burner
on and off. The thermostat used on this heater
senses the room temperature. At times the
Shutting Off Heater
Turn control knob clockwise
OFF position.
1. Open screen.
2. Follow steps 1 through 8 under Lighting
Instructions, page 18.
3. With control knob in the PILOT position,
strike a match, and hold near pilot. Press
in control knob; pilot should light.
200020-01A
OPERATION
THERMOSTATIC CONTROL OPERATION

TO TURN OFF GAS TO APPLIANCE

to the

MANUAL LIGHTING PROCEDURE

www.usaprocom.com
Note: Please wait one minute after shut-
ting off heater to allow the control valve
to reset before starting again.
10. Make sure heater screen is in place before
operating heater.
11. If heater will not operate, follow the in-
structions To Turn Off Gas To Appliance,
and call your service technical or gas
supplier.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
WARNING: If input gas
type is NG, make sure NG pilot
burner ignites. If input gas type
is LP, make sure LP pilot burner
ignites.
room may exceed the set temperature. If so,
the burner will shut off. The burner will cycle
back on when room temperature drops below
the set temperature. The control knob can
be set to any comfort level between High (5)
and Low (1).
Shutting Off Burner Only (pilot
stays lit)
Turn control knob clockwise
PILOT position.
4. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
5. Make sure the heater screen is in place
before operating heater.