Regulator Pressure Setting
Regulator Pressure Setting
* For purposes of input adjustment.
Heater Dimensions (H x W x D)
Carton Dimensions (H x W x D)
Only a qualified agency should install and
replace gas piping, gas utilization equipment
or accessories, and repair and equipment ser-
vicing. The term "qualified agency" means any
individual, firm, corporation, or company that
either in person or through a representative
is engaged in and is responsible for:
SAFETY PILOT
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS/pilot shuts off the heater if there is not
enough fresh air.
PIEZO IGNITION SYSTEM
This heater is equipped with an electronic
piezo control system. This system requires
AAA batteries (provided).
200020-01A

SPECIFICATIONS

MODELS
Gas Type
Maximum Input Rating 32,000 BTU/Hr
Minimum Input Rating 14,500 BTU/Hr
Inlet Gas Pressure*
(inches of water)
MODELS
Gas Type
Maximum Input Rating 32,000 BTU/Hr
Minimum Input Rating
Inlet Gas Pressure*
(inches of water)
Ignition
Stove Weight
Shipping Weight

QUALIFIED INSTALLING AGENCY

PRODUCT FEATURES

www.usaprocom.com
FBD400TCC-M-HC/MO
Natural
4" W.C.
Max. 10.5" W.C.
Min. 5" W.C.
FBD400RTCC-M-HC/MO
Natural
N/A
4" W.C.
Max. 10.5" W.C.
Min. 5" W.C.
ALL MODELS
Electronic Piezo Ignitor
29.5" x 29.1" x 15.6"
31.1" x 31.5" x 18.1"
a) Installing, testing, or replacing gas piping
or
b) Connecting, installing, testing, repairing,
or servicing equipment; that is experienced
in such work; that is familiar with all precau-
tions required; and that has complied with
all the requirement of the authority having
jurisdiction.
THERMOSTAT HEAT CONTROL
The control automatically cycles the burner
on and off to maintain a desired room tem-
perature.
2 GAS OPTIONS AVAILABLE
Your heater is equipped to operate on either
Propane/LP or Natural gas. The heater is
shipped from the factory ready for connect-
ing to Propane/LP. The heater can easily be
changed to Natural gas by having your quali-
fied installer follow the instructions on page
11 and the markings on the heater.
Propane/LP
32,000 BTU/Hr
24,500 BTU/Hr
9" W.C.
Max. 14" W.C.
Min. 11" W.C.
Propane/LP
32,000 BTU/Hr
N/A
9" W.C.
Max. 14" W.C.
Min. 11" W.C.
69.5 lbs.
79.5 lbs.
5