Operation Check & Aeration Settings Adjustment; Remote Control Handset Wall Holder Installation - Valor 739IRN Installation And Owner's Manual

Dv gas insert (rocks) 739irn (ng) & 739irp (lpg)
Hide thumbs Also See for 739IRN:
Table of Contents

Advertisement

Operation Check & Aeration Settings Adjustment
INSTALLATION
Operation Check
Turn the fi replace fl ame up and down using the
remote control to confi rm that the full range of inputs
is achieved—see the remote control operation
instructions on pages 24–27.
Aeration Settings
Light the fi re and allow the unit to warm up for 10–15
minutes to evaluate the fl ame picture. Burners are
equipped with an adjustable shutter to control primary
aeration. See the fi gures below. The shutters are
factory-set to an aeration gap which will give optimum
performance for the vast majority of installations.
Air Shutters
NG Air Shutter
Slider & Cover

Remote Control Handset Wall Holder Installation

The remote control kit for this fi replace
comes complete with a wall-mounted holder.
This holder is not required in all installations
but is provided as an optional feature for
those customers who wish to mount the
remote handset to the wall.
To install the holder to the wall, fi nd a
convenient location and use the hardware
provided with the kit. See the diagram below
for required hardware and confi gurations.
Note that the holder can be installed at the
base of a light switch plate.
IMPORTANT. The location of the remote
control handset is important to assure proper
temperature regulation. To obtain a constant
temperature, we recommend that the handset should be between 3 and 15 feet away from the appliance but not
directly above it. We also advise that the handset should be located away from any other heat source and not in
direct sunlight as this may affect the temperature sensor located in the remote handset.
20
NG
Close
Open
Close
Open
Packing Contents:
1 Wall Bracket A
2 Screws B
1 Screw C
2 Wall Anchor D
1 Spacer E
(detach before assembly)
1 Wall Bracket F
In a few unusual installations, the fl ame picture may
be improved by adjusting the aeration. The need for
adjustment should be determined only by operating the
appliance with the ceramic logs and window installed.
Increasing aeration (open) will cause the fl ames
to appear more transparent and blue showing more
ceramic log glow.
Decreasing aeration (close) will cause the fl ames to
appear more yellow or orange showing less ceramic
log glow.
Too little aeration may result in black carbon
forming and dropping into the fi rebox.
Flashback
shield (for
LPG only)
LPG Air Shutter
Slider
Alternative 2
Alternative 1
LPG
Close
Open
Alternative 3
Switch Plate

Advertisement

Table of Contents
loading

This manual is also suitable for:

739irpLegend 739irnLegend 739irp

Table of Contents