Operation Check & Aeration Settings Adjustment
INSTALLATION
Operation Check
Turn the fi replace fl ame up and down using the
remote control to confi rm that the full range of inputs
is achieved—see the remote control operation
instructions on pages 45–49.
Aeration Settings
Light the fi re and allow the unit to warm up for 10–15
minutes to evaluate the fl ame picture. The burner is
equipped with an adjustable shutter to control primary
aeration (NG only). The shutter is factory-set to an
aeration gap which will give optimum performance for
the vast majority of installations.
Air Shutter
Accessing air shutter

Remote Control Handset Wall Holder Installation

The remote control kit for this fi replace comes
complete with a wall-mounted holder. This
holder is not required in all installations but
is provided as an optional feature for those
customers who wish to mount the remote
handset to the wall.
To install the holder to the wall, fi nd a
convenient location and use the hardware
provided with the kit. See the diagram below for
required hardware and confi gurations. Note that
the holder can be installed at the base of a light
switch plate.
IMPORTANT. The location of the remote
control handset is important to assure proper
temperature regulation. To obtain a constant temperature, we recommend that the handset
should be between 3 and 15 feet away from the appliance but not directly above it. We also
advise that the handset should be located away from any other heat source and not in direct
sunlight as this may affect the temperature sensor located in the remote handset.
40
Remove front middle
platform support
In a few unusual installations, the fl ame picture may
be improved by adjusting the aeration. The need for
adjustment should be determined only by operating the
appliance with the fuel bed and window installed.
Increasing aeration will cause the fl ames to appear
more transparent and blue showing more ceramic rock
glow.
Decreasing aeration will cause the fl ames to appear
more yellow or orange showing less ceramic rock glow.
Too little aeration may result in black carbon
forming and dropping into the fi rebox.
To access the air shutter, remove the front middle
platform as indicated. The air shutter is located under
the burner as shown in the illustrations.
Open
Close
Setting air shutter
Packing Contents:
1 Wall Bracket A
2 Screws B
1 Screw C
2 Wall Anchor D
1 Spacer E
(detach before assembly)
1 Wall Bracket F
Alternative 1
Air shutter
Injector elbow
Injector elbow bracket,
burner side
Alternative 2
Alternative 3
Switch Plate