7. PRE-OPERATION SETTINGS
DC
0-10
V
Principal parameters and descriptions are as follows. Set these parameters according to operational
requirements.
-
Setting Method: Use the parameter unit for setting parameters. See page 30 for
descriptions of settings.
DC
0 5 V
Parsmetere
Frequency refer-
ence signal
Select 5V or 1 O V
D-crlptlon
Set the frequency reference voltage signals input across termi-
nals 2 and
5.
Set parameter num-
ber 73 to 1.
0-10
v
4""
Set parameter nurn-
ber 73 to 0.
I *
The inverter is set as
shown above when
it
I
isshipped.
Note:
Be
sure to select the 0-5
VDC
input if you connect a fre-
auencv reference Dotentiometer (variable resistor).
Related Functlons
Input selection 5 V/10
V
(pa-
rameter number 73)
(Continued on next page)