Mitsubishi Electric Freqrol Z024-UL Instruction Manual page 9

Vvvf transistor inverter
Table of Contents

Advertisement

PRECAUTIONS ON USE
Parsmetar number
20
39
Carefully read the entire instruction manual.
Panmeter name
Frequency for 5 V input
Frequency for 20 rnA input
Control varlabie at shipment
'60.5-63
HZ
.
1.
These parameters refer to maximum frequency when the Inverter is supplied.
When the inverter is supplied, the inverter output frequency is 60 Hz when the external frequency
reference signal is DC
5
V (1OV) or 20 mA. However, parameters (see below) that set the
maximum output frequency have a set value over
60
Hz.
'
The parameter at shipment (60 Hz) that appears on pages 69,70 and 71 of this instruction
manual should be interpreted to
be
the above.
Note:
To adjust the relationship between the frequency reference signal and output frequency, follow the
setting procedures described on page 29 of this instruction manual.
- 3 -

Hide quick links:

Advertisement

Table of Contents
loading