Notes
on
Use wlth Slngle-Phase Power Supply
(1) The single-phase power supply must be connected to the power supply side terminals
R
and
S
*
of the inverter.
(2) The inverter must be used with the power supply of sufficient power supply capacity. If the
power supply capacity Is small, the output voltage will be varied greatly by the load.
NFB
Single-phase AC power supply
200
to 230V
50 /
60HZ
Motor
Circuit Example1
-25-