*e,
Magnitude of braking torque is not continuous regenerative torque, but shown as the average
deceleration torque (which varies according to motor
loss)
when the motor alone was decelerated
from 60
Hz
in the shortest time. BU type brake unit
is
not compatible. If a brake resistor is used,
braking toque for models 0.4K to I .5K is approximately 150%, and that for models 2.2K and 3.7K is
approximately
100%.
Monitor signal for output frequency or for motor current can be selected. Use the parameter unit
(parameter number 70) to select output signal specification.
Motor current may not be correctly indicated depending on operation status (during
acceleration/deceleration, light load, etc.).
This temperature range is applicable for short time temperature change such as transportation.
When undervoltage or instantaneous power failure has occurred, alarm display and alarm output are
not provided but the inverter itself is protected.
'7.
'8.
*9.
' 1 0 ,
-118-