SETTING AND ADJUSTMENT
OF
OUTPUT SIGNAL
FOR
MONITORING
I
. . . . . . . . . . . . . . . . . . . .
.
. . . . .
.
. .
.
.
.
,
. . . . . .
. .
.
.
. .
.
.
. .
.
Set value
1
Output terminal FM is used to connect an indicator that monitors
operating status. Output frequency or motor current (output
current) can be lndlcated by selecting either one.
Motor
current (output current)
I
Set value
0
I
Frequency
to be detected.
(initial setting)
I
. . .
.
If motor current is selected as the output from terminal FM, the
relationship between motor current and output signal can be
adjusted. Set current
(%)
against terminal FM's output of 1440
Hz.
Output frequency from terminal FM varies in proportion
to
the
current.
I
Set
value
Ratio
to
the rated output current
of
inverter
I
0-200
(%)
~
Initial setting
:
150%
t
Output frequency
or
motor current
t
Motor current
(%)
150
-95-