SETTINQ APPLICABLE LOAD
1
sa
value
0
It is possible to select output characteristics (V/F characteristics) that are optimum for the
application or load characteristics.
If you use the Mitsubishi constant torque motor, set values from 10 to 13 which are listed in the
right-hand table. By setting one
of
these values, it
is
possible to set electronic thermal relay
exclusively for the constant torque motor in the electronic thermal relay parameter number 9.
Output char.cteri.tlc8
Constant torque load (initial setting)
2
3
10
I l l
Reduced torque load
Elevation load (zero boost setting at reverse rotation)
Elevation load (zero boost setting at toward rotation)
Constant torque load
11
12
For the
~
constant
torque motor
Reduced torque load
Elevation load (same as that of set value 2)
13
- 8 6 -
Elevation load (same as that of set value 3)