Alarm Summary Table - Electrolux TC3 Service Manual

Washing machines with electronic control system
Hide thumbs Also See for TC3:
Table of Contents

Advertisement

8 ALARM SUMMARY TABLE

Description
Water fill difficulty during
washing
Water leaks
Drain difficulty during washing
Drain difficulty during drying
Faulty TRIAC for drain pump
Drain pump TRIAC "sensing"
circuit faulty
Technical Support – ADL
Possible fault
 Tap closed.
 Water pressure too low.
 Drain pipe improperly positioned.
 Water fill solenoid valve faulty.
 Leaks from pressure switch water circuit.
 Pressure switch faulty.
 Faulty wiring.
 Main circuit board faulty.
 Drain pipe improperly positioned.
 Water pressure too low.
 Water fill solenoid valve faulty.
 Leaks/clogging of pressure switch water circuit.
 Pressure switch faulty.
 Drain tube kinked/clogged/improperly positioned.
 Drain filter clogged/dirty.
 Faulty wiring.
 Pressure switch faulty.
 Drain pump rotor blocked.
 Drain pump faulty.
 Main circuit board faulty.
 Drain pipe kinked/clogged/improperly positioned.
 Drain filter clogged/dirty.
 Faulty wiring.
 Drain pump faulty.
 Pressure switch faulty.
 Main PCB faulty.
 Faulty wiring.
 Drain pump faulty.
 Main circuit board faulty.
 Main circuit board faulty.
Cycle is paused with door locked
Cycle is paused with door locked
Cycle is paused (after 2 attempts)
Cycle is paused
Safety drain cycle - Cycle stops with door open
Safety drain cycle - Cycle stops with door
unlocked
34/43
Machine status/action
599 75 85-45 Rev. 00
Reset
START/RESET
START/RESET
START
ON/OFF
RESET
START/RESET
RESET
RESET

Hide quick links: