Electrolux TC3 Service Manual page 35

Washing machines with electronic control system
Hide thumbs Also See for TC3:
Table of Contents

Advertisement

Description
Malfunction in electronic pressure
switch circuit
Calibration error of the electronic
pressure switch
Overflow
Internal pressure chamber is
clogged (water level does not
change for at least 30 sec. of
drum rotation)
Technical Support – ADL
Possible fault
 Wiring; Electronic pressure switch.
 Main electronic circuit board.
 Drain tube kinked/clogged/improperly positioned.
 Solenoid valve faulty.
 Drain filter clogged/dirty.
 Drain pump faulty.
 Leaks from pressure switch water circuit.
 Pressure switch faulty.
 Wiring; main circuit board.
 Water fill solenoid valve faulty.
 Leaks from pressure switch water circuit.
 Faulty wiring.
 Pressure switch faulty.
 Main circuit board faulty.
 Motor belt broken.
 Pressure switch hydraulic circuit clogged.
Cycle stops with door locked
Cycle is paused
Cycle interrupted
Safety drain cycle
Drain pump continues to operate (5 mins. on,
then 5 mins. off, and so on)
Heating phase is skipped
35/43
Action
Machine status
599 75 85-45 Rev. 00
Reset
RESET
START/RESET
RESET
RESET