14.6 Table of alarm codes

Alarm
Description
E11
Poor water fill before wash cycle
Difficulty in water fill during drying (maximum
E12
time 3 min. water fill in drying during the wash
load unrolling phase)
E13
Water leaks
E21
Poor draining
Difficulty in water fill during drying or drying
E22
condenser clogged (anti-boiling pressure switch
closed on "FULL")
E23
Defective triac for drain pump
Malfunction in sensing circuit on triac for drain
E24
pump
Malfunction in pressure switch circuit (frequency
E31
of signal from pressure switch out of limits)
Electronic pressure switch improperly calibrated
(level on electronic pressure switch differs from
E32
0-66 mm after initial calibration drain and when
anti-boiling pressure switch is on "empty").
Inconsistency between level on electronic
pressure switch and level on anti-boiling
E33
pressure switch 1-2 (fault persists for at least 60
sec.).
Inconsistency between level on electronic
pressure switch and level on anti-boiling
E34
pressure switch 2 (fault persists for at least 60
sec.).
SOI/DT 2005-01 dmm
Possible fault
Tap closed or water pressure too low; Drain tube improperly
positioned; Water fill solenoid valve is defective; Leaks from water
circuit on pressure switch; Pressure switch defective; Wiring defective;
Main board defective.
Tap closed or water pressure too low; solenoid valve; pressure switch
water circuit; pressure switches; wiring; main board.
Drain tube improperly positioned; Water pressure too low;
Water fill solenoid valve is defective; Water circuit on pressure switch
is leaking/clogged; Pressure switch defective.
Drain tube kinked/clogged/improperly positioned; Drain filter
clogged/dirty; Drain pump defective; Pressure switch defective; Wiring
defective; Main board defective; Electrical current leak between
heating element and ground.
Drain hose kinked; filter clogged: drying condenser clogged; drain
pump faulty; pressure switches faulty; wiring; main circuit board
defective; current leakage between heater and ground.
Drain pump defective; Wiring defective; Main board defective.
Main board defective.
Pressure switch;
Wiring;
Main board;
Tap is closed or water pressure is too low;
Solenoid valve;
Water circuit on pressure switches; pressure switches;
Wiring; main board;
Pressure switch defective;
Electrical current leak between heating element and ground; Heating
element; Wiring defective;
Main board defective.
Water circuit;
Pressure switch defective;
Electrical current leak between heating element and ground; Heating
element; Wiring defective;
Main board defective.
Water circuit;
57/65
Action/machine status
Cycle is paused with door locked
Cycle is paused
Cycle is paused with door locked
Cycle is paused
Cycle is paused
Emergency drain procedure - Cycle
stops with door unlocked
Emergency drain procedure - Cycle
stops with door unlocked
Cycle stops with door locked
Cycle is paused
Emergency drain procedure - Cycle
stops with door unlocked
Emergency drain procedure - Cycle
stops with door unlocked
Reset
Start
Start
Start
Start
Start
OFF/reset
OFF/reset
OFF/reset
Start
OFF/reset
OFF/reset