Alarm Summary Table - Electrolux EWM09312 Service Manual

Hide thumbs Also See for EWM09312:
Table of Contents

Advertisement

4.5 ALARM SUMMARY TABLE

Alarm
Description
E00
Water fill difficulty during
E11
washing
E13
Water leaks
E21
Drain difficulty during washing
E23
Faulty triac for drain pump
Drain pump triac "sensing"
E24
circuit faulty.
Malfunction in electronic
E31
pressure switch circuit
Calibration error of the
E32
electronic pressure switch
E35
Overflow
Internal pressure chamber is
clogged (water level does not
E38
change for at least 30 sec. of
drum rotation)
E41
Door open
E42
Problems with door lock
Faulty triac supplying power to
E43
door delay system
Faulty sensing by door delay
E44
system
Faulty sensing by door delay
E45
system triac
2012 SOE/DT-mdm FCPD-dp
Guide to diagnostics of EWM09312 electronic controls
Possible fault
Tap closed or water pressure too low; Drain pipe improperly
positioned; Water fill solenoid valve faulty; Leaks from water circuit
on pressure switch; Pressure switch faulty; Wiring faulty; Main PCB
faulty.
Drain pipe improperly positioned; Water pressure too low;
Water fill solenoid valve faulty; Water circuit on pressure switch is
leaking/clogged; Pressure switch faulty.
Drain pipe kinked/clogged/improperly positioned; Drain filter
clogged/dirty; Wiring faulty; Pressure switch faulty; Drain pump
rotor blocked; Drain pump faulty; Main PCB faulty.
Wiring faulty; Drain pump faulty; Main PCB faulty.
Main circuit board faulty.
Wiring; Electronic pressure switch; Main PCB;
Drain pipe kinked/clogged/improperly positioned; Solenoid valve
faulty; Drain filter clogged/dirty; Drain pump faulty; Leaks from
pressure switch hydraulic circuit; Pressure switch faulty;
Wiring; main PCB;
Water fill solenoid valve faulty; Leaks from water circuit on pressure
switch; Wiring faulty; Pressure switch faulty; Main PCB faulty.
Motor belt broken; Water circuit on pressure switch clogged.
Check whether the door is closed properly;
Wiring faulty; Door safety interlock faulty;
Main circuit board faulty.
Wiring faulty; Door safety interlock faulty;
Electrical current leak between heating element and ground;
Main PCB faulty.
Wiring faulty; Door safety interlock faulty;
Main circuit board faulty.
Main circuit board faulty.
Main circuit board faulty.
Machine status/action
--------------------------------
Cycle is paused with door locked
Cycle is paused with door locked
Safety drain cycle - Cycle stops with
door open.
Safety drain cycle - Cycle stops with
door unlocked
Cycle stops with door locked
Cycle interrupted. Safety drain cycle.
Drain pump continues to operate
(5 min. on, then 5 min. off. etc.)
Heating phase is skipped
(Safety drain cycle)
(Safety drain cycle)
(Safety drain cycle)
15/69
Reset
START/RESET
START/RESET
START
Cycle is paused
ON/OFF
(after 2 attempts)
RESET
RESET
RESET
RESET
Cycle is paused
START/RESET
RESET
RESET
Cycle is paused
START/RESET
Cycle is paused
START/RESET
RESET
Cycle blocked
RESET
Cycle blocked
RESET
Cycle blocked
Page
20
22
24
26
28
28
29
30
31
32
36
40
42
42
599 75 18-74 Rev.00