Washing machines with electronic control system
Hide thumbs Also See for TC3:
Table of Contents

Advertisement

Description
Electronically controlled valve
blocked with operating flowmeter
Data transfer error between
Weight sensor and main PCB
Problems with weight sensor
(no signal or outside the limits)
Drain filter clogged
(drain phase too long)
Overdosing of detergent
(too much foam during drain
phases)
Aqua control system intervention
Water fill pressure too low, no
signal from flowmeter and
electronically controlled valve
is open
Unbalanced load
Reset
Technical Support – ADL
Possible fault
 Faulty wiring.
 Solenoid valve faulty/blocked.
 Circuit board faulty.
 Faulty wiring.
 Weight sensor faulty.
 Circuit board faulty.
 Faulty wiring.
 Weight sensor faulty.
 Main board faulty.
 Drain filter clogged/dirty.
 Drain hose blocked/kinked/too high.
 Excessive detergent dosing.
 Drain hose kinked/blocked.
 Drain filter clogged/dirty.
 Water leaks onto base frame.
 Aqua control device faulty.
 Tap closed.
 Water fill pressure too low.
 Final spin phases skipped.
 If it continues, replace the main board.
Cycle stops with door locked
Drain pump continues to operate (5 mins. on,
then 5 min. off, and so on)
Warning displayed at the end of cycle
Warning displayed after 5 attempts or by the
specific LED
Appliance drains
41/43
Action
Machine status
----------------
----------------
----------------
----------------
599 75 85-45 Rev. 00
Reset
RESET
START/RESET
START/RESET
RESET
ON/OFF
RESET
RESET
START/RESET
----------------