Description
Door open
Problems with door lock
Faulty triac supplying power to
door delay system
Faulty "sensing" of door delay
system
Faulty sensing by door delay
system TRIAC
Technical Support – ADL
Possible fault
Check whether the door is closed properly.
Faulty wiring.
Door safety interlock faulty.
Main circuit board faulty.
Faulty wiring.
Door safety interlock faulty.
Electrical current leak between heating element and ground.
Main circuit board faulty.
Faulty wiring.
Door safety interlock faulty.
Main circuit board faulty.
Main circuit board faulty.
Main circuit board faulty.
Cycle is paused
Cycle is paused
Safety drain cycle
Cycle blocked
Safety drain cycle
Cycle blocked
Safety drain cycle
Cycle blocked
36/43
Action
Machine status
599 75 85-45 Rev. 00
Reset
CLOSE THE
DOOR
START/RESET
RESET
RESET
RESET