Description
Insufficient heating during the
washing phase
Overheating during washing
phase (temperature higher than
88°C for more than 5 min.)
Heating element power relay
faulty (inconsistency between
sensing and relay status)
Current leak to the ground
Heating element interrupted
Heating relay sensing faulty
Heating element power relay
faulty (inconsistency between
sensing and relay status)
Technical Support – ADL
Possible fault
Faulty wiring.
NTC probe for wash cycle faulty.
Heating element faulty.
Main circuit board faulty.
Faulty wiring.
NTC probe for wash cycle faulty.
Heating element faulty.
Main circuit board faulty.
Main circuit board faulty.
Current leakage between heating element and ground.
Faulty wiring.
Heating element for washing interrupted (thermal fuse open).
Main circuit board faulty.
Main circuit board faulty.
Faulty wiring.
Current leakage between heating element and ground.
Main circuit board faulty.
The heating phase is skipped
Safety drain cycle
Cycle stops with door open
Safety water fill
Cycle stops with door closed
The heating phase is skipped
Cycle stops with door locked
Safety water fill
Cycle stops with door closed
38/43
Action
Machine status
----------------
599 75 85-45 Rev. 00
Reset
START/RESET
RESET
ON/OFF
RESET
START/RESET
START
ON/OFF
RESET
RESET
ON/OFF
RESET