Fans
Fuser unit cooling fan (FCF)
1. Disconnect the fan connector from its mating harness connector.
2. Remove the screws (4) securing the fan and fan plate to the duct.
Duct
Fuser unit cooling fan
Fan plate
Screws (4)
Fan connector
Figure 4–92
Replacement Procedures
4–125