Exiting The Diagnostics System - Electrolux TC2 Service Manual

Condenser dryer with electronic control system
Hide thumbs Also See for TC2:
Table of Contents

Advertisement

IMPORTANT!
The alarms remain active during component diagnostics testing. If an alarm should be displayed, turn
the programme selector to the first position to exit the alarm situation, and then continue the testing cycle
(if the alarm is not repeated).
In order to check for correct operation of the floating switch and the pump, the sump is filled with
approximately 0.7 litres of water.
For correct control of the conductimetric sensor in a condition of short-circuit (position 7), remove the
cover and create a short-circuit between the two half-shells of the drum or between the front shell and
ground. After entering this phase, the time available for creation of the short circuit is just one second;
therefore, prepare the short circuit before turning the programme selector knob to position eight
(it is advisable to do this in a position in which the drum is stationary, then pass quickly to this position).
If the short circuit is not performed correctly, the electronic board will display alarm E32 (sensor
frequency too low). To exit the alarm condition, turn the programme selector knob to the first position.
Open the condenser access panel and check that the switch operates correctly. The buzzer will emit
four "beeps" (in different tonalities), repeated every 7 seconds.

9.2 Exiting the diagnostics system

To exit the diagnostics system, turn the programme selector knob to zero to switch the appliance OFF,
then switch it ON and OFF again.