4.11 Adjusting the level of conductivity (on some models)

The conductivity of the water used to wash the fabrics varies from zone to zone. The conductimetric sensor
is calibrated to a standard value: any major variations in the level of conductivity may affect the final drying
result (i.e. the washing may be too dry or too humid):
These variations are more noticeable in the "slightly damp" or "iron-ready" cycles; the "cupboard dry cycles
are almost entirely unaffected by variations in conductivity.
The sensitivity of the conductimetric sensor can be adjusted according to the conductivity of the water.

4.11.1 Procedure

To access adjustment mode:
1. Turn the programme selector to switch on the
appliance.
2. In selection mode (set-up), simultaneously
press buttons 3 (Delicate) and 6
(start/pause).
On TC2 and TC3 models
Hold the buttons down till "C0" appears on the
first 2 digits and the buzzer sounds (about 5
seconds).
Adjusting the level of conductivity:
Press the 6 button sequentially (start/pause):
the level of conductivity is indicated by the
lighting of the horizontal hyphens of the last
digit.
On TC5 models
Hold the buttons down till the pilot lamps placed
above the buttons start to flash and one of the
pilot lamps that indicate the drying phase remains
on:
Adjusting the level of conductivity:
Push the START/PAUSE button sequentially: the
conductivity level will be indicated by the pilot
lamps of the single phases.
Memorizing the new setting:
1. Simultaneously press buttons 3 (Delicate)
and 6 (start/pause).
2. Hold the buttons down until the drying cycle
reappears on the display and the buzzer
sounds (about 5 seconds).