7.8 Door interlock
The door interlock is an electromechanical device which powers the electrical loads only when the door is
correctly closed and the programme selector knob is turned (ON/OFF - closed).
The interlock features a child safety device so that, in case of necessity, the door can be opened by pressing
from inside the appliance.
Opened door:
the lever holds down the button
of deviator "A"; in this position
contacts 1-2 are closed. In some
models they power the drum
light when the main switch is off.
Position of connectors
SOI/ADL
Closing the door:
the latch (1) rotates cam (2): this
movement releases lever (3)
and the button on the deviator
"A" changes position, thus
closing contacts 1-3 and
powering all components of the
appliance (cutting power out to
the drum light)
25/57
Pushing the door opening
button:
the main electronic board
powers the coil; the core (1),
moves the anchor (2), releasing
the cam (3). The cam, rotating,
moves the lever (4) which closes
the contacts of the deviator "A"
in position 1-2, and releases the
door latch (5).
Wiring diagram
A = Commutator in open
position
contacts 1-2: 0 Ω
contacts 1-3: ∞ Ω
C = Door opening coil
contacts 7-8: ~ 90Ω
599 38 46-21