10.5 Table of alarms

Alarm
Description
E00
No alarm.
E21
Canister fill pump triac faulty.
E22
Triac "sensing" circuit for the canister fill pump faulty Electronic board faulty.
E31
Conductimetric sensor signal frequency too high.
E32
Conductimetric sensor signal frequency too low.
It is displayed in the last alarm, if position 8 is NOT
E33
OK.
E45
Door closure sensor.
E51
Motor power triac short-circuited.
E52
Intervention of motor overheating safety cut-out.
E53
Motor triac "sensing" circuit faulty.
E54
Motor inoperational.
SOI/ADL
Wiring faulty; Electronic board faulty.
Electronic board faulty.
Wiring faulty; Brushes worn/faulty; Electronic
board faulty.
Wiring faulty; Brushes worn/faulty; Electronic
board faulty.
Door interlock faulty; Wiring faulty; Electronic
board faulty.
Motor faulty; Wiring faulty; Electronic board faulty.
Motor faulty; Intervention of motor overheating cut-
out; Wiring faulty; Electronic board faulty.
Electronic board faulty.
Excessive wash load; Voltage too low;
Motor/transmission system inoperative.
34/57
Possible fault
---
599 38 46-21
Action/machine status
---
Cycle interrupted.
Cycle interrupted.
Alarm activated only during diagnostics.
Cycle interrupted.
Alarm activated only during diagnostics.
Cycle interrupted.
Cycle interrupted.
Power to the heater unit and reversal of the
direction of rotation are interrupted. If the
problem does not re-occur, the alarm is
memorized and the cycle continues. If the
fault persists after several attempts to supply
power (about 35 min.), alarm E51 is
generated.
Cycle interrupted.
Cycle paused after several attempts at
powering the motor.
Reset
command
---
OFF
OFF
---
OFF
---
OFF
OFF
OFF
OFF
Start