Wiring Length Guidelines; Preparing Captive Wires; Wiring A Power Connection; Wiring Guidelines - Indirect Power (Via Poe) - AMX MAX-CSD 10 Operation And Reference Manual

Amx corporation max video encoder & video decoder operation/reference guide
Table of Contents

Advertisement

MAX-CSE and MAX-CSD10 Installation

Wiring length guidelines

Refer to the following table for the wiring length information related to the target MAX unit:
MAX-CSE and MAX-CSD10 @ 500 mA
Wire size
18 AWG
20 AWG
22 AWG
24 AWG

Preparing captive wires

You will need a wire stripper and flat-blade screwdriver to prepare and connect the captive wires.
Never pre-tin wires for compression-type connections.
1. Strip 0.25 inch (6.35mm) of insulation off all wires.
2. Insert each wire into the appropriate opening on the connector (according to the wiring diagrams
and connector types described in this section).
3. Tighten the screws to secure the wire in the connector. Do not tighten the screws excessively, as
doing so may strip the threads and damage the connector.

Wiring a power connection

To use the 2-pin 3.5mm mini-Phoenix connector with a 12 VDC-compliant power supply, the incoming
PWR and GND cables from the external source must be connected to their corresponding locations on
the connector (FIG. 3).
PWR +
GND -
To the rear of the MAX unit
FIG. 3
2-pin mini-Phoenix connector wiring diagram (direct power)

Wiring Guidelines - Indirect Power (via PoE)

Power-over-Ethernet (PoE) can be used to indirectly provide DC power to this 802.3af-compliant device
via the unused wire pairs in the UTP or STP Ethernet cable (RJ-45 pins 4, 5, 7, and 8). PoE power is
overridden if a direct power feed (via the rear 2-pin PWR connector) is detected.
Any 802.3af-compliant PoE switch (such as the NXA-ENET24 PoE) can automatically detect the MAX
device by its authenticated PoE signature and sense its required load before applying power to the PoE
Ethernet port on a target device.
PoE connections work with all existing Category (CAT) 3, 4, 5, 5e or 6 network
cabling (including patch cables and patch-panels, outlets, and other connecting
hardware) without requiring modification.
10
Maximum wiring length
216.76 feet (66.07 meters)
137.61 feet (41.94 meters)
88.78 feet (27.06 meters)
54.15 feet (16.50 meters)
Power Supply
MAX-CSE/MAX-CSD10 Operation/Reference Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Max-cseMax-csd10Max-cse10