Displaying Stream Content
4. If you are feeding a microphone audio signal into the rear MAX-CSE microphone connector, you
could use the Microphone Gain field to enter an audio level (0 - 99) associated with the gain used by
the rear microphone input.
At any time, the user can choose to mute the incoming microphone signal by either
toggling the state of the Microphone icon located at the top of the page or entering a
value of zero into the Mic Gain field.
5. Click the Apply button to save the encoding profiles to the MAX-CSE.

Setting up a streaming page within TPDesign4

1. Launch TPDesign4 (default location is Start > Programs > AMX Control Disc > TPDesign4 >
TPDesign4). Refer to the TPDesign4 Instruction Manual for more detailed instructions of these
procedures.
2. From the menu bar, select File > New (or click the New Project toolbar button).
3. From within the Step 1 dialog, enter a generic Job name and use the Panel Type drop-down arrow to
choose a VG-Series panel (1200VG, 1500VG, or 1700GVG).
4. Fill in the fields within the remaining New Project Wizard dialogs and click Next at the end of each
dialog to proceed final dialog.
5. Click the Finish button in the last dialog to close the wizard and proceed to the first generic page
which is ready for you to start adding pages, popup pages, and buttons.
6. Add a new page to the project by selecting Page > Add Page (or click the toolbar icon) which opens
the Add Page dialog, where you can then enter a descriptive name for the new page in the Name
field such as Full Screen Video (UDP).
7. Press the Button Draw Tool (CTRL+U) to draw a square button.
8. Press the Selection Tool (CTRL+L) to grab the new button and stretch it to fill a desired area of the
page. For our procedures, we stretched the new button to fill the entire available are of the newly
created page (FIG. 44).
9. With the button currently selected and active, navigate to the left section of the Workspace and find
the Button Properties Control window (FIG. 44).
10. Click the States tab of the Button Properties Control window to show a list of all states associated
with the selected button. Each state represented in the States tab is a collapsed folder containing the
state properties for that particular state (On/Off/All).
11. Double-click the All States + symbol to expand this folder (FIG. 45) and locate the Video Fill field.
12. Use the Video Fill drop-down arrow to select the Streaming Video option (A in FIG. 45).
13. Within the newly added Streaming Source field, enter the Transport Protocol, IP Address of the
MAX-CSE, and Target Video Port (B in FIG. 45).
68
For the purpose of these procedures, we've chosen to use a Job Name of Test and selected an
NXD-1700VG touch panel.
Note that although a page cannot directly be setup to display a video stream, a user can create
a full-screen button on that same page which can be configured to fill its contents with a video
stream.
When using a UDP Transport Protocol, enter the following into the Streaming Source field:
udp://IP Address of MAX-CSE:Target Video Port set on the UI page.