Gas/electricity failure during operation

Interruption to the electricity or gas supply will turn your heater off. Restart will be
required. This is a safety feature to ensure unattended starts do not occur.
After interruption to the electricity supply
To restart your heater after electricity has been restored follow the steps for 'Turning the heater on' detailed on
the previous page.
After interruption to the gas supply
The instant the gas supply is interrupted the heater will attempt re-ignition for a period of 60 seconds. If the
heater has not started after this period the gas control will go back to 'gas-lock-out', but the fan will remain on to
cool the appliance.
To restart your heater once the gas has been restored:
1.
Ensure there is gas supply to the heater.
2. To reset the gas control turn OFF the heater by pressing the ON/OFF button once.
3. In quick succession (within five seconds) press the ON/OFF button three times (turn ON, then OFF, then ON
again).
Neo operation guide: 11907-E 05-14 | 17

Hide quick links: