Mantels and surrounds

Mantels and surrounds, made of combustible materials, are allowed providing they are
outside the minimum clearances shown below. Due to the number of different sized Neo
frames, the dimensions are taken from the edge of the glass.
C
A
Mantel height from top of glass
B
Mantel depth at A - 400 mm (vertical clearance)
For every 50 mm of added mantel depth, there must be an additional 100 mm of vertical
clearance. For example; a mantel depth (B) of 350 mm will require 600 mm (A) of vertical
clearance.
C
Surround from side of glass
D
Surround projection at C - 200 mm (side clearance)
E
Minimum mantel height from floor (when heater is mounted on
the floor)
F
Minimum width for surround

Hearths

A hearth is not necessary, but can be used for decorative purposes or protection of
sensitive flooring if required. It must not obscure the front of the fire.
8 | Neo operation guide: 11907-E 05-14
B
F
D
A
E
400 mm minimum
250 mm maximum
200 mm minimum
250 mm maximum
910 mm maximum
915 mm minimum