3. Corrective actions at warning

Take one of the following actions as
applicable, in case a warning condition
has occurred.
å B u z z e r a n d R P M R e d u c t i o n :
Overheat Warning or Water Intake
Clogged Warning
1. Shift into neutral.
2. Check that cooling water is
running out of the check port.
3. If no water is running out, check if
the water intake is clogged.
∫ Buzzer and Lamp: Low Oil Warning
1. Shift into neutral.
2. Turn the main switch off.
3. Fill the oil tank.
4. Turn the main switch on to check
if the buzzer and lamp are off.
ç E n g i n e R P M i s l i m i t e d t o
approximately 6,000 and "X 1,000
RPM" indicator flashes. (120A2.
l40A2) / to approximately 5,900 rpm
(90A) / to approximately 6,150 rpm
(60C. 70C).
Over-revolution protection function
is turned on.
WARNING SYSTEM
Notes
This function may be turned on in case
a propeller has run out of the water.
In such a case, the function will be
turned off automatically after the
propeller gets into the water again.
1. Shift into neutral.
2. Check the propeller for damage.
In case the propeller is damaged,
return to port immediately at a low or
medium speed to replace it with new
one. If the propeller is not damaged,
go to step 3. (The propeller pitch
may be unfit for the outboard.)
3. Replace the current propeller with
a proper pitch. For selection of the
propeller, consult with the dealer.
∂ Engine RPM is indicated "00" and
limited to approximately 1,500.
(l20A2. 140A2)
Red / yellow lead of cord assembly
B. (For location of the lead, refer to
WIRING DIAGRAM of this manual) is
not connected.
1. Shift into neutral.
2. Turn off the engine.
3. Check if the lead is connected.