Table For Intervention Conditions Of Input/Output Stations - IBM Tape Library Magstar 3494 Operator's Manual

Ibm magstar 3494 tape library operator guide
Table of Contents

Advertisement

Table 17. Intervention Required Conditions relating to other library components (continued)
Intervention Required Condition
Message
The library is full.
Probable Cause
An attempt was made to insert cartridges into the library
and there are no available cells in the library other than
the convenience I/O station or the high-capacity facility.
Message
The system has failed. A service call is required.
Probable Cause
A major failure in of the systems in the library has
occurred.

Table for Intervention Conditions of Input/Output Stations

Table 18. Intervention Required Conditions relating to Input/Output Stations or facilities
Intervention Required Condition
Message
The convenience I/O station is full.
Probable Cause
All of the cells of the convenience I/O station are full and
at least one additional cartridge is queued to be ejected
to the convenience I/O station.
Message
The high-capacity facility is full.
Probable Cause
All of the cells of the high-capacity facility are full and at
least one additional cartridge is queued to be ejected to
the high-capacity facility.
Message
The convenience I/O station door is open.
Probable Cause
The convenience I/O station door has been left in the
open position for greater than 5 minutes or there is an
eject operation queued for the convenience I/O station
and the door is open.
286
Magstar 3494 Tape Library Operator Guide
Resolution Actions
1. Cartridges must be ejected from the library before
more cartridges can be inserted into the library
system.
2. This condition cannot be cleared by selecting it from
the list of actions. Instead, this condition is cleared
automatically by the library system when space
becomes available in the library.
Call your service representative.
Resolution Actions
1. Remove all cartridges from the convenience I/O
station.
2. This condition cannot be cleared by selecting it from
the list of actions. Instead, this condition is cleared
automatically by the library system when space
becomes available in the convenience I/O station.
1. Place the library system in pause mode.
2. Open the appropriate enclosure door.
3. Remove all cartridges from the high-capacity facility.
4. Close the enclosure door.
5. Place the library system in auto mode.
6. This condition cannot be cleared by selecting it from
the list of actions. Instead, this condition is cleared
automatically when empty cells are found during
inventory update.
1. Close the convenience I/O station door.
2. This condition cannot be cleared by selecting it from
the list of actions. Instead, this condition is cleared
automatically by the library system when the
convenience I/O station door is closed.

Advertisement

Table of Contents
loading