Manual Mode To Auto Mode; Initialization State To Auto, Pause, Or Manual Mode; Auto Mode To Pause Mode (Forced); Operational State Transitions - IBM Tape Library Magstar 3494 Operator's Manual

Ibm magstar 3494 tape library operator guide
Table of Contents

Advertisement

3. The operations necessary to park the cartridge accessor and remove its power
4. The library completes the change to Manual mode (see "Pause Mode to Manual
5. An attention message is sent to all attached hosts indicating that the state of the

Manual Mode to Auto Mode

When an operator wants to select Auto mode while the 3494 is in Manual mode,
the operator must use the library manager. The library performs the operations to
move to Pause mode and then move to Auto mode. All pop-up windows indicate
that the 3494 is in Auto Pending as it is moving through Pause mode. In addition,
an attention message is only sent when Auto mode is entered, not for the
intermediate Pause mode. During the change from Manual to Auto mode, the
following steps are performed:
1. The System Summary window indicates that the operational mode is Auto
2. The 3494 completes the change to Pause mode as described in "Manual Mode
3. The library completes the change to Auto mode as described in "Pause Mode to
4. An attention message is sent to all attached hosts indicating that the state of the

Initialization State to Auto, Pause, or Manual Mode

During the initialization-complete state, the library manager determines which
operational mode to enter. The determination is made by examining the database
and the state of the cartridge accessor power. When the determination is made, the
change to the selected mode occurs. The steps taken during the transition are the
same as an operator request when the library is in Pause mode and Offline state.

Auto Mode to Pause Mode (Forced)

If a severe error or condition is detected, and the error or condition is such that it is
not possible to continue automated operation, the library is forced into Pause mode.
Power is immediately removed from the cartridge accessor and any operations in
progress are stopped. When the library manager enters Pause mode, it sends an
attention message to all attached hosts indicating that the state of the library
changed. The state-change message and an associated unsolicited unit check
indicates the error recovery action (ERA).
The Pause Mode pop-up window directs the operator to open the library. In most
cases, the cartridge accessor cannot be parked.

Operational State Transitions

The tape library is only in one operational state at any time.
are performed (see "Auto Mode to Pause Mode (No Error)" on page 69).
Mode" on page 70).
library changed.
Pending.
to Pause Mode" on page 70.
Auto Mode" on page 68.
library changed.
Chapter 4. Operational Modes and States, and Informational States
71

Advertisement

Table of Contents
loading

Table of Contents