Table for DFSMS Library Failure Messages or Exception Conditions

Table 12. DFSMS Messages Based on Library Failure or Exception Conditions
Resulting Console Message
CBR3711I Unexpected ERA code ERA-code from
library library-name .
An error has been detected during processing in tape
library library-name . The library returned a unit check with
error recovery action code ERA-code , which is an
unexpected or inappropriate response to the library
request.
It is likely that the microcode in the library and the
software are not at the correct level.
CBR3712I Unexpected completion code, CC= cc , from
library library-name .
An error has been detected during processing in tape
library library-name . An unexpected or inappropriate
completion code cc has been received from the library.
It is likely that the microcode in the library and the
software are not at the correct level.
CBR3721I Library library-name in manual mode.
Library library-name is in manual mode and cannot
complete or accept library audit requests. Any pending
audit requests queued within the library when it was
placed in manual mode are failed resulting in this
message. Any subsequent audit requests issued to the
library will also fail and result in this message.
CBR3722I Library library-name equipment check.
A library hardware failure has been detected by the
library or one of the associated tape subsystems. The
failing library component must be repaired before library
requests can be completed successfully.
CBR3724I Volume volser does not exist in library
library-name .
Volume volser does not reside in library library-name . It is
possible that the volume has been ejected from the
library by another host system.
CBR3725I Library library-name command reject for
volume volser . Library error code= error-code .
A request for a library operation with volume volser has
been rejected by library library-name . The error code
indicates the reason for the rejection, but is included for
diagnostic purposes only.
It is likely that the microcode in the library and the
software are not at the correct level.
Action
Contact your service representative.
Contact your service representative.
When the library has returned to auto mode, resubmit the
audit requests.
Contact your service representative.
1. Use the ISMF mountable tape volume list function to
examine the current state of the volume under
DFSMS.
2. Determine where the volume is and re-enter it into the
library's input station.
Contact your system administrator.
Chapter 8. Problem Determination Procedures
269