Pin Configuration
PIN
FUNCTION
1
RS232-TX
2
RS232-RX
3~6
ALARM INPUT
7
EXTERNAL ALARM NC Under the normal operation, COM connects with NC and disconnects from NO.
8
EXTERNAL ALARM
NO.
9
GND
10
RS485-B
11
RS485-A
12~13
PIN OFF
14
ALARM RESET
15
EXTERNAL ALARM
COM
16~17
GND
DC12V +
DC12V +
DC12V +
GND
GND
GND
DESCRIPTION
DVR can be controlled remotely by the keyboard of PC by using RS-232 serial
communication signals.
DVR can be controlled remotely by the keyboard of PC by using RS-232 serial
communication signals.
To connect the wire from ALARM INPUT ( PIN 3 -- 6 ) to GND ( PIN 9 ) connector,
DVR will start recording and the buzzer will be on.
When "MENU -> CAMERA -> ALARM" is set to "Low" : When the alarm input
signal is " Low ", the unit starts to record and buzzer.
When "MENU -> CAMERA -> ALARM" is set to "High" : When the alarm input
signal is " High ", the unit starts to record and buzzer.
But when any alarm is triggered, COM disconnects with NC and connects with
NO.
Attention: The voltage restriction is under AV/DC 30V.
Under the normal operation, COM disconnects with NO. But when any alarm is
triggered, COM connects with NO.
Attention: The voltage restriction is under AV/DC 30V.
Signal GND.
DVR can be controlled remotely by the keyboard of PC by using RS-485 serial
communication signals.
DVR can be controlled remotely by the keyboard of PC by using RS-485 serial
communication signals.
Connecting the wire from ALARM RESET (PIN 14) to GND (PIN 9) connector will
disable alarms. An external signal to ALARM RESET (PIN 14) can be used to
reset both ALARM OUTPUT signal and DVR's internal buzzer. When any alarm
has been triggered, the signal becomes "Low", and all alarm activities will be
stopped. Under the normal operation, the signal remains "High".
Under the normal operation, COM disconnects with NO. But when any alarm is
triggered, COM connects with NO.
Attention: The voltage restriction is under AV/DC 30V.
Earth GND
Solder Side
Solder Side
of DSUB
of DSUB
15PIN
15PIN
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
15 14 13 12 11 10 9
15 14 13 12 11 10 9
15 14 13 12 11 10 9
16
16
16
17
17
17
PIN Connection Application
PIN Connection Application
When the magnetic contact is opened, the
When the magnetic contact is opened, the
alarm will be triggered and the recording is
alarm will be triggered and the recording is
on. At the same time, COM connects with
on. At the same time, COM connects with
NO and the siren with strobe starts wailing
NO and the siren with strobe starts wailing
and flashing.
and flashing.
NOTE: Please go to MENU -> ADVANCE ->
NOTE: Please go to MENU -> ADVANCE ->
DETECTION -> DETECTION SETUP, and
DETECTION -> DETECTION SETUP, and
set ALARM to LOW on the local machine.
set ALARM to LOW on the local machine.