Table 54: Set config zoning parameters
InteropAutoSave
Default Visibility

Examples

The following is an example of the SET CONFIG PORT command:
HP StorageWorks 2/8q Fibre Channel Switch Management User Guide
ZONING
Initiates an editing session in which to change switch zoning attributes. The system
displays each parameter one line at a time and prompts you for a value. For each
parameter, enter a new value or press Enter to accept the current value shown in
brackets.
Parameter
2/8q FC Switch #> admin start
2/8q FC Switch (admin) #> config edit
2/8q FC Switch (admin-config) #> set config port 1
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current
value.
If you wish to terminate this process before reaching the end of the
list
press 'q' or 'Q' and the ENTER key to do so.
Configuring Port Number:
------------------------
AdminState
(1=Online, 2=Offline, 3=Diagnostics, 4=Down)
LinkSpeed
(1=1Gb/s, 2=2Gb/s, 3=Auto)
PortType
(GL / G / F / FL / Donor)
SymPortName
(string, max=32 chars)
ALFairness
(True / False)
DeviceScanEnable (True / False)
ForceOfflineRSCN (True / False)
ARB_FF
(True / False)
InteropCredit (decimal value, 0-255)
Description
Available only when the InteropMode parameter is True, this
parameter enables (True) or disables (False) the saving of
changes to active zone set in the switch's permanent memory.
See
"Set config threshold
default is True. (not supported)
Disabling the Autosave parameter can be useful to prevent
the propagation of zoning information when experimenting
with different zoning schemes. However, leaving the Autosave
parameter disabled can disrupt device configurations should
a switch have to be reset. For this reason, the Autosave
parameter should be enabled in a production environment.
Enables (All) or disables (None) communication among the
switch's ports/devices and the fabric in the absence of an
active zone set. The default is All.
1
Command Line Interface
parameters" on page 140. The
[Online]
[Auto
]
[GL
]
[Port1 ]
[False ]
[True
]
[False ]
[False ]
[0
]