e. Select Enabled or Disabled from the Suppress RSCNs on Zone set activations drop-down list.
The default state is disabled.
When the parameter is enabled, attached devices do not receive notification following any
change to the fabric's active zone set.
When the parameter is disabled, attached devices (registered through the fabric format
domain register) do receive notification following any change to the fabric's active zone set.
5.
Click Activate to save the information. The message Your changes to the Operating
Parameters configuration have been successfully activated is displayed.
6.
Set the switch online:
a. Select Operations > Online State. The Operations page is displayed with the Online State
tab selected.
b. Click Set Online. The message Your changes have been successfully
activated is displayed.

Set fabric parameters

The switch must be set offline to configure fabric parameters. To configure the parameters:
1.
Set the switch offline as follows:
a. At the View window, select Operations at the left side of the panel. The Operations panel
opens with the Switch Beacon page displayed.
b. At the Operations panel, select the Online State tab, then click Set Offline. The message
Your operations changes have been successfully activated is displayed.
2.
At the View window, select Configure at the left side of the panel. The Configure panel opens
with the Ports page displayed.
3.
Click the Switch tab, then select the Fabric Parameters tab. The Switch page is displayed with
the Fabric Parameters options
Figure 40
Switch page—Fabric parameters tab
(Figure
40).