Table 33: Faceplate display messages (Continued)
One of the selected ports is currently in use as
a donor port to allow for extended credits on
another port. Modifications to donor ports are
not permitted.
Port reset failed.
or
Request to reset to factory defaults has failed.
or
Request for switch reset failed.
Request for switch reset failed because admin
access was not available.
Reset will complete shortly. There is a brief loss
of connectivity with switch.
Resetting the switch will disrupt traffic. Do you
wish to continue?
or
Deactivating the active zone set will disrupt
traffic. Do you wish to continue?
Resetting to factory defaults will disrupt traffic
and cause current switch configuration to be
lost.
Showing Last Known State.
The file currently exists.
The online port loopback test can only be
performed on a single port at a time. There
are multiple ports selected. Continue with
loopback test on first selected port.
The zoning information you are about to edit
is incomplete. If you apply changes you will
possibly lose zoning information.
Unable to perform request. Switch is currently
unreachable.
HP StorageWorks 2/8q Fibre Channel Switch Management User Guide
Message
User action
Deselect the donor ports, and then retry the
operation.
Verify that the user has permissions to modify
the configuration on the switch, that the switch
is reachable in the fabric, and that the fabric is
reachable from the user's workstation, and
then retry the configuration change.
Verify that another user is not currently
modifying the switch configuration, using
either the management application, or a telnet
login, or any application, and then retry the
operation.
Wait for the switch to become reachable
again. This may take up to one minute.
The requested action causes the servers and
storage systems attached to the fabric to lose
communications until the switch reset is
complete and the fabric has re-initialized. If
this is acceptable, continue; otherwise cancel
the operation.
This action is disruptive to the fabric. Verify
that this is the action that you want to take.
The switch state displayed by the application
cannot be updated because the switch has
become unreachable. Verify that the switch is
reachable in the fabric, and that the fabric is
reachable from the user's workstation.
The selected switch archive file already exists.
If it is acceptable to overwrite the file, continue.
Otherwise, return and select a different
archive file.
Select only a single port, and then retry the
operation.
The application has not been able to
completely read the current zoning database
from the switch. If the user edits the incomplete
database information and applies the
changes, any information which has not been
read from the switch is lost.
If this is acceptable, continue. Otherwise,
verify that the switch is reachable in the fabric,
and that the fabric is reachable from the user's
workstation then refresh the display and verify
that the zoning database has been completely
read, and then retry the operation.
Verify that the switch is reachable in the
fabric, and that the fabric is reachable from
the user's workstation, and then retry the
operation.