D.
007-5900-001
Appendix D
BMC Error Codes
The BMC may generate beep codes upon detection of failure conditions. Beep codes are sounded
each time the problem is discovered (for example, on each power-up attempt) but are not sounded
continuously. Common supported codes are listed in
In
Table
D-1, each digit in the code is represented by a sequence of beeps whose count is equal to
the digit.
Table D-1
BMC Beep Codes
Beep Code
Reason for Beep
1-5-2-1
No CPUs installed or first CPU socket is
empty.
1-5-2-4
MSID Mismatch.
1-5-4-2
Power fault: DC power is unexpectedly
lost (power good dropout).
1-5-4-4
Power control fault (power good assertion
timeout).
1-5-1-2
VR Watchdog Timer sensor assertion
1-5-1-4
The system does not power on or
unexpectedly powers off and a power
supply unit (PSU) is present that is an
incompatible model with one or more
other PSUs in the system.
Table
D-1.
Associated
Sensors
Supported
CPU Missing sensor
Yes
MSID Mismatch
Yes
sensor.
Power unit—power
Yes
unit failure offset.
Power unit—soft
Yes
power control failure
offset.
VR Watchdog timer
PSU status
55