Figure 75 Sensor calibration / setup parameters - Page 1
SENSOR CALIBRATION/SETUP (page 1 of 3)
S601
S602
S603
S604
S605
S606
S607
S608
S609
S610
S611
Return Temperature—This parameter adjusts the return temperature reading from the actual
sensor to compensate for any error of the sensor or to match other sensors in the room.
Calibrated Return Temperature—This parameter shows the adjusted temperature value of the
return sensor. This value is the actual sensor reading (+ or -) the offset "Return Temperature".
Return Humidity—This parameter adjusts the return humidity reading from the actual sensor to
compensate for any error of the sensor or to match other sensors in the room.
Calibrated Return Humidity—This parameter shows the adjusted humidity value of the return
sensor. This value is the actual sensor reading (+ or -) the offset "Return Humidity".
Digital Scroll 1 NTC—This parameter adjusts the digital scroll 1 NTC reading from the actual sen-
sor to compensate for any error or drift of the sensor.
Calibrated Digital Scroll 1 NTC—This parameter shows the adjusted Digital Scroll 1 NTC sensor
value. This value is the actual sensor reading (+ or -) the offset "Digital Scroll 1 NTC".
PASSWORD (Actual Level 3) ????
Event Description
High Head Pressure C 1
High Head Pressure C 2
Loss of Airflow
Change Filters
Water Alarm
Condensing Pump Alarm
Glycool Status
Unit On
for next/previous unit
then
to change parameter
PASSWORD (Actual Level 3)
Return Temperature
Calibrated Return Temperature
Return Humidity
Calibrated Return Humidity
Digiscroll 1 NTC
Calibrated Digiscroll 1 NTC
Digiscroll 2 NTC
Calibrated Digiscroll 2 NTC
for next/previous unit
then
to change parameter
UNIT 01
ID Output # Status
No
9
No
9
No
10
No
11
No
12
No
13
No
14
No
15
to select parameter
to confirm
UNIT 01
to select parameter
to confirm
84
Service Menu Parameters
0
0
0
0
0
0
0
1
????
+0.0°F
73.0°F
+0.0°F
48.4%
0°F
84°F
0°F
98°F