3.
Press the GROUP SELECT button again for more than one second. This returns the 
7H4385‐49 to the default status mode to monitor RX (receive) and TX (transmit) 
activity. 
Table
4‐1 describes the LED indications and provides recommended actions as 
appropriate.
Note: The terms used in
• Flashing indicates LED is flashing randomly.
• Blinking indicates LED is flashing at a steady rate (approximately 50% on, 50% off).
• Solid indicates a steady LED light. No pulsing.
• Alternating indicates LED is flashing in a steady rate other than 50% on, 50% off.
Table 4-1 LANVIEW LEDs
LED
Color
MGMT
Off
Green
Amber
CPU
Off
Amber
Green
Red
Green and
Amber
Table 4-1
indicate the following:
State
Off. This DFE module is NOT
the Management Module.
Solid. This module is the
designated Management
Module.
Flashing. This is a
temporary indication that the
DFE module is saving data.
Power off.
Blinking. DFE module in
process of booting.
Solid. Testing.
Blinking. Image starts
running.
Solid. Functional.
Solid. Processor in reset.
Blinking. Indicates that the
DFE module is in the process
of shutting down.
DFE-Platinum Series Hardware Installation Guide 4-3
Recommended Action
None.
None.
None.
Ensure chassis has adequate power.
None.
If the LED remains amber for several
minutes, contact Enterasys Networks
for technical support.
None.
None.
None.
None. This state is activated when the
OFFLINE/RESET switch is pressed for
less than 1 second to start the process
of an orderly shutdown.
While in this state, do not remove any
DFE module.
Using LANVIEW