Overview of DFE Module Shutdown Procedure

Table 4-2 Troubleshooting Checklist (continued)
Problem
User parameters (IP
address, device and
module name, etc.)
were lost when the
module power was
cycled, the front
panel OFFLINE/
RESET switch was
pressed.
Overview of DFE Module Shutdown Procedure
The DFE modules installed in a Matrix E7, Matrix N3, Matrix N5, or Matrix N7 chassis are 
interdependent and operate under a single IP address as a single, distributed switch 
system (hardware, databases, and persistent storage). In this operating environment, the 
DFE module must shut down in an orderly fashion to ensure that the other modules in the 
system and other devices on the network are notified of the impending change. The 
device(s) can then make intelligent decisions and stabilize the network before the change 
is made, thereby increasing network availability.
You can shut down a DFE module in an operating system using the OFFLINE/RESET 
switch shown in Figure
Recommended shutdown procedure ("Recommended Shutdown Procedure Using 
OFFLINE/RESET Switch" on page 4‐9)
Last resort shutdown procedure (not recommended)
Procedure Using OFFLINE/RESET Switch" on page 4‐10) 
4-8 Troubleshooting
Possible Cause
Position of Mode switch (7),
Persistent Data Reset, was
changed sometime before
either cycling power or
pressing the OFFLINE/RESET
switch, causing the user-
entered parameters to reset to
factory default settings.
Clear Persistent Data that was
set through Local
Management.
The DFE module was moved
either from slot-to-slot or from
chassis-to-chassis.
Caution: Do not remove a DFE module from an operating chassis system before reading
the following information and instructions.
Precaución: Antes de retirar los módulos DFE del chasis en funcionamiento, lea las
siguientes instrucciones y la información suministrada.
4‐2. There are two procedures to shut down a DFE module.
Recommended Action
Reenter the lost parameters as
necessary. Refer to the Enterasys Matrix
DFE-Platinum Series Configuration Guide
for the instructions to configure the
DFE module.
If the problem continues, contact
Enterasys Networks for technical support.