Add Or Remove Non−Communicating Equipment; Maintenance Timers - Lennox icomfort Wi-Fi Setup Manual

Icomfort wi-fi thermostat
Hide thumbs Also See for icomfort Wi-Fi:
Table of Contents

Advertisement

Add or Remove Non−communicating equipment
Figure 7 (previous page) shows how to access the Add or Remove Non−
communicating equipment" screen.
Adding Non−Communicating Outdoor unit
for adding/removing an outdoor unit.
Adding Humidifier
The procedures in figure 9 describe adding a non−
communicating humidifier which will be controlled by the icomfort Wi-Fit
thermostat through the H" or HUM" terminals on the furnace or air handler.
Adding Dehumidifier
The procedures in figure 10 describe adding a
non−communicating dehumidifier controlled by the icomfort Wi-Fit thermo-
stat through the DH" output on the furnace or air handler.
NOTICE
For details about how the humidification and dehumidification
modes operate and how to configure those modes, see additional in-
formation beginning on Page 18.
HUMIDITY CONTROL TIPS
S
S
See figure 8 for details
S
Adding non−communicating accessories
timer reminders to accessories is a simple process of installing" the device,
which effectively tells the thermostat to activate access to its service timers.
Timers are available for two (2) filters, Humidifier pad, UV bulb maintenance
and the PureAirt Air Purification system.
Page 9
The standard humidification mode is Basic" (humidifier is energized
during a call for heat, if there is a humidification demand).
Sensed outdoor temperature, required for some features, is provided
from one of the following sources:
A
downloaded via Wi−Fi when available (primary source),
B
sensor furnished with icomfortt−enabled outdoor units,
C
separate outdoor sensor connected to the furnace or air handler
outdoor sensor" connections.
NOTE − If no source for outdoor temperature is present, Basic and
Precision Dew Point Control" modes are not available.
If you do not have the ability to select or adjust the Humidity RH set-
point on the Indoor Humidity" button, the control is set for Display
Only." In the installer program, go the equipment button and select
System" and press the edit button. Select Humidification Control
Mode" and press edit. Choose Basic," Precision," Basic Dew Point
Control" or Precision Dew Point Control" and press save.
icomfort Wi-Fit 7−Day Programmable Communicating Thermostat
Adding maintenance

Hide quick links:

Advertisement

Table of Contents
loading