Configure Dehumidification (No Dehumidifier Installed) - Lennox icomfort Wi-Fi Setup Manual

Icomfort wi-fi thermostat
Hide thumbs Also See for icomfort Wi-Fi:
Table of Contents

Advertisement

Adjust a setting... Configure Dehumidification (no dehumidifying device installed)
(skip if default Basic" dehumidification mode is desired)
System Devices
System
Furnace
Thermostat
2 Stage AC Unit
Power (120VAC) Humidifier
System
2nd Stage Differential
Staged Delay Timers
2nd Stage Delay
Dehumidification Control Mode
Humidification Control Mode
OK/Humid Boundary
Outdoor Temperature Reading
Dehumidification Control Mode
Select one
Display Only
3a
Precision
save
3b
Figure 16. Adjust dehumidification when not using Humiditrol or an auxiliary dehumidifier
To adjust a setting, highlight it,
then press Edit
System
1a
1b
Dehumidification Control Mode
back
current value:
Display Only
2a
2b
System
Staged Delay Timers
back
Balance Point Control
Basic
Dehumidification Control Mode
Humidification Control Mode
Auto Changeover − Humidif. Deadband
Max Humidification Setpoint
Min Dehumidification Setpoint
OK/Humid Boundary
Outdoor Temperature Reading
cancel
9:39 am Aug 15, 2012
Pre−adjustment REQUIREMENTS:
1st, NO physical dehumidification device has been installed.
2nd, configure the thermostat for dehumidification as follows:
1. In the system devices" list, use the arrows (1a) to highlight System.
Press edit (1b).
about
2. In the System" list, use the arrows (2a) to highlight Dehumidification
Control Mode. The current value defaults to Display Only. Press edit
(2b).
edit
3. Touch one of the radio buttons (3a) to select the mode of dehumidification
control; press save (3b).
reinstall
4. Use arrows (4a) to highlight any red colored text in the list (e.g. select Min
Dehumidification Setpoint). Press edit (4b).
5. Use arrows (5a) to make changes; press save (5b). Change other red
settings (e.g. Auto Changeover − Humidif. Deadband) using a similar
next
process.
6. Press the back button to return to Adjust a setting..." screen.
NOTE − If the defaults are correct, you do not have to make any changes, but you
must press save (5b). When all red text is gone, the back button will appear; press it
edit
to return to the Add or Remove Non−communicating equipment?" screen.
reset
Dehumidification Control Mode
current value:
Precision
4a
please view and save all
red settings
icomfort Wi-Fit 7−Day Programmable Communicating Thermostat
Page 17
Min Dehumidification Setpoint
4b
edit
reset
6
5b
back
Range is 40 to 60
Default is 45, inc:1
set−to
45
5a
save
cancel

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents